Metri-Pack Series
delphi-connectors
2.57
S
S
NOTE: Specifi cations in this catalog are for general reference only and are subject to change without notice. To verify product information, please contact a Delphi representative.
Sealed System Application Information
*The test data are based on single circuits in free space and were generated using a "Lumped
Resistance" model. This model does not account for all of the variables that would be present in an
actual application. For actual product performance, contact your regional support representative.
CABLE
RANGE
(
mm
2
): ....... 0.50-5.0
CURRENT
RANGE
(
AMPS
): ........ 0-46
TEMP
RANGE
O
C
: ........... -40 to 125
RESISTANCE
: ...... <10m
@20mV
VOLTAGE
DROP
: ...... <3.0mV/amp
CENTERLINE
SPACING
(
mm
): ..... 10.8
BLADE
WIDTH
(
mm
): ................ 6.3
100
80
60
40
20
0
5.0
50
40
30
20
10
0
3.0
0.50
630
Series Terminals
C Tin Plated
0.80
1. 0
2.0
5.0
2.0
3.0
1.0
0.80
0.50
0 10203040 50
25 50 75 100 125
TEMPERATURE RISE ABOVE
AMBIENT (25
o
C ) VS CURRENT*
CURRENT (AMPS)
TEMPERATURE DERATING CURVES*
AMBIENT TEMPERATURE (
O
C
)
630
630 Metri-Pack Cavity Plug*
Part # Cavity Inside Diameter Material Color
12059255 9.8mm
Silicone Green
*Cavity plugs seal unused female and male cavities.
630 Male Connector Sealed
# Cavities Connector Color Material TPA
3
15358681 Black PBT 30% GF
12045699
630 Male Terminals Sealed
Part # Cable Range (mm
2
) Material Plating
12064736 5.0
Tin Brass Tin
12064737 3.0
Tin Brass Tin
12064735 2.0-1.0
Tin Brass Tin
12064734 0.80-0.50
Tin Brass Tin
Male Connector
CPA
(Connector Position
Assurance)
Male Terminal
Cable Seal
TPA
(Terminal Position
Assurance)
SECTION NOTES:
. Due to rigid tolerances of connector cavities, it is critical to
meet all crimp dimensions as specifi ed.