064 Series Unsealed Specifications
MicroHVT & Micro64 Mating Terminals
064 Series
delphi-connectors
U
U
4.4
Temperature Rise vs. Current*
0.64 mm square tin-plated pin mated to MicroHVT terminal 每
0.50 mm
2
cable
Steady State Current (Amps)
3 0
2 5
2 0
1 5
1 0
5
0
Maximum Recommended
Continuous Current
01 2 34 5 67
Female Terminal
Application Guidelines MicroHVT
Micro64
Typical Cable Applications
0.35 mm
2
- 0.50 mm
2
TWP (SAE J-1128)
0.35 mm
2
- 0.50 mm
2
TWP (SAE J-1128)
0.75 mm
2
FLRY-A (DIN 72551)
0.75 mm
2
FLRY-A (DIN 72551)
0.80 mm
2
TXL Reduced Wall (SAE J-1128)
0.80 mm
2
TXL Reduced Wall (SAE J-1128)
Current Range
0 - 7 amps
0 - 5 amps
Temperature Range
-40∼C to +85∼C
-40∼C to +85∼C
Resistance
<20 m次 @ 20 mV
<20 m次 @ 20 mV
Voltage Drop
<20 mV/amp
<20 mV/amp
Centerline Spacing
2.54 mm (terminal-to-terminal and row-to-row)
2.54 mm (terminal-to-terminal and row-to-row)
Header Pin
0.64 mm square, tin-plated
0.64 mm square, tin-plated
Temperature Rise vs. Current*
0.64 mm square tin-plated pin mated to Micro64 terminal -
0.50 mm
2
cable
Steady State Current (Amps)
Maximum Recommended
Continuous Current
3 0
2 5
2 0
1 5
1 0
5
0
0 1 2 34 5
Temperature Derating Curve*
0.64 mm square tin-plated pin mated to Micro64 terminal 每
0.50 mm
2
cable
Assumes 85
C maximum operating temperature
Ambient Temperature (
C)
Maximum Recommended
Continuous Current
8
7
6
5
4
3
2
1
0
2 5 3 5 4 5 5 5 6 5 7 5 8 5
* Data based on laboratory testing of a single circuit in free air. The lab test does not account for all of the variables that would be present in an actual application.
Temperature Rise/Derating Curves
Micro64
MicroHVT
Temperature Derating Curve*
0.64 mm square tin-plated pin mated to MicroHVT terminal 每
0.50 mm
2
cable
Assumes 85
C maximum operating temperature
Ambient Temperature (
C)
Maximum Recommended
Continuous Current
25 35 45 55 6 5 75 85
1 3
1 2
1 1
1 0
9
8
7
6
5
4
3
2
1
0